Skip to main content
Til toppen

CAN Repeater

CAN-Repeater can be used for the physical coupling of two or more segments of a CAN-Bus system. CAN networks have a bus (line) topologies, but using CAN-Repeater tree and star topologies and long branches are realizable.

The CAN-Repeater splits the CAN network in two galvanic isolated networks and works bit-wise. It means that all CAN nodes in the different segments receive the same bit information. Electrical each segment presents a CAN Bus (line).

A CAN Repeater can not extend the CAN-network because of its delay time that has an effect like an additional line. It is more suitable for adaption to the available topography, for the galvanic isolation of network segments and to increase the number of possible nodes.

CAN-Repeater and Star Coupler do not influence the real-time behavior of the system, because the transfer behavior complies with one network.

Using CAN repeaters, the distance between the two furthermost CAN nodes must not be larger than the maximal CAN bus length for the used CAN baud rate.

Visning
CAN-CR100 With bus termination resistor

CAN-CR100 Repeater with 2 x CAN HS (switchable to CAN FD), Galvanic isolation, CAN termination resistor, 2 x Screw terminals, DIN rail mount. With integrated termination resistors.

1.01.0210.20000
CAN-CR100 Without bus termination resistor

The Ixxat CAN-CR100 repeater with two CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation, DIN Rail mount

1.01.0210.20200
CAN-CR120/HV, 2 isolated (HV) CAN-ports, screw terminals w/C

CAN-CR120/HV repeater with two CAN/CAN FD interfaces provides a galvanic isolation up to 3 kV for enhanced protection of network segments. With integrated termination resistors, DIN Rail Mount

1.01.0210.20010
CAN-CR120/HV, 2 x Cu, w/o bus termination resistor

CAN-CR120/HV repeater with two CAN/CAN FD interfaces provides a galvanic isolation up to 3 kV for enhanced protection of network segments. Without termination resistor, DIN Rail mount

1.01.0210.20210
CAN-CR200

CAN-CR200 repeater with two CAN interfaces and one CAN backbone interface improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation. DIN Rail mount

1.01.0067.44010
CAN-CR210/FO Glass fiber version with F-SMA connector

CAN-CR210/FO repeater with two CAN interfaces, one of which is a Fiber Optic interface (FSMA plug), enables the conversion of CAN signals from copper wire to fiber optics, DIN rail mount

1.01.0068.45010
CAN-CR210/FO Glass fiber version with ST connector

CAN-CR210/FO repeater with two CAN interfaces, one of which is a Fiber Optic interface (ST plug), enables the conversion of CAN signals from copper wire to fiber optics, DIN rail mount

1.01.0068.46010
CAN-CR220 CANbus repeater, Galv.isolator

CAN-CR220 repeater with two CAN interfaces provides a galvanic isolation up to 4 kV DC/3.5 kV AC for 1 second, enhancing the protection of network segments, DIN rail mount

1.01.0067.44400
CAN-CR300, 4 isolated CAN-ports, screw terminals w/ CAN-term

CAN-CR300 repeater with four CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation. With integrated termination resistors, DIN Rail mount

1.01.0210.40000
CAN-CR300, 4 x Cu, w/o bus termination resistor

CAN-CR300 repeater with four CAN/CAN FD interfaces improves the CAN bus load capacity, establishes a physical coupling of bus systems and offers galvanic isolation, DIN Rail mount

1.01.0210.40200
T-Bus Connector

The Ixxat T-Bus connector is designed for linking multiple CAN Repeaters with a backbone bus to a central hub. It supports the creation of star and tree network topologies, thereby extending the coverage of the CAN network and simplifying the wiring process.

1.04.0073.00000
Lenker
Min side