ControlNet Media Connector
inkl. mva.
Networks and Communication Products, ControlNet Media Connector
Egenskaper for produkt/familie
- Supports Master Device redundancy
- Provides seamless RSLogix 5000™ environment integration through Add-On Profiles, which automatically identifies field devices and configures them to their default settings
- Protects the integrity of a FOUNDATION Fieldbus H1 or Profibus-PA segment by automatically isolating faulty drops and restoring power when faults are corrected
- Helps simplify large network commissioning through diagnostic parameters such as Power Supply Voltage, PA Bus Voltage (A & B bus), PA Bus Current (A & B bus), and Unit Internal Temperature
- Supports multiple levels of device and media redundancy
- Supports EtherNet/IP Media redundancy
- Supports FDT/DTM Technology, allowing direct access to field device diagnostics and parameters using an FDT frame, such as FactoryTalk® AssetCentre
- Operates as a true PA master without requiring a DP network, DP master, coupler device, or external power conditioner
- Simplifies commissioning through onboard advanced diagnostics, including a node-specific PA bus oscilloscope trace that can be viewed within the RSLogix5000 Add-On Profile
- Displays useful field bus diagnostic information via status LEDs
- Supports ControlNet Media redundancy
- Use with the 1786-RPFS repeater
- Links an EtherNet/IP™ network to a single Profibus-PA segment
- Links an ControlNet™ network to a single Profibus-PA segment
- Self-contained, panel, or DIN-rail mountable device
- Links an EtherNet/IP™ network to a single H1 segment
- Helps simplify large network commissioning through diagnostic parameters such as Power Supply Voltage, H1 Bus Voltage (A & B bus), H1 Bus Current (A & B bus), and Unit Internal Temperature
- Use a repeater adapter to supply a maximum of 1.6 A @ 5V DC of current to power the repeater modules
- Contains the FOUNDATION Fieldbus Registered FF H1 Stack developed by Rockwell Automation®
- Connects and powers as many as 16 field devices, eliminating the need for external power conditioners
- Provides all basic diagnostic information in the input assembly
- Provides trunk open-circuit and short-circuit monitoring and reroutes trunk connections for extended availability
- Simplifies commissioning through onboard advanced diagnostics, including a node-specific H1 bus oscilloscope trace that can be viewed within the RSLogix5000 Add-On Profile
- Supports as many as 24 PA field devices
- Includes 200 micron cable
- Provides seamless RSLogix5000™ integration through Add-On Profiles, which automatically identifies field devices and configures them to their default settings
- Links a ControlNet™ network to a single H1 segment
Spesifikasjoner | |
---|---|
ControlNet Media | ControlNet Media Connector |
Lengde | 11.001 |
Høyde | 8.499 |
Livssyklus | Active Mature |
Datablad | ||
---|---|---|
Spec Sheet Filnavn: ag-pa002_-en-p.pdf Filtype: application/pdf |
Last ned |